ibm,lpar-perftools RTAS Call
This RTAS call provides access to platform-level facilities for
performance tools running in a partition on an LPAR system. Platforms may
require platform-specific tools, beyond the scope of this architecture,
to make this call available.
R1--1.
For the Performance Tool Support option: The platform
must implement the LPAR option.
R1--2.
For the Performance Tool Support option: RTAS must
implement the
ibm,lpar-perftools call using the argument call
buffer defined by
.
Argument Call Buffer
ibm,lpar-perftools
Parameter Type
Name
Values
In
Token
Token for
ibm,lpar-perftools
Number Inputs
5
Number Outputs
2
Subfunction
1: Convert hypervisor IAR value to method name.
Work Area Address High
Most significant 32 bits of real address of work
area
Work Area Address Low
Least significant 32 bits of real address of work
area
Work Area Size
Size of work area in bytes
Sequence Number
Integer representing the sequence number of this call.
First call in sequence starts with 1, following calls (if
necessary) use the
Next Sequence Number returned from the
previous call.
Out
Status
-1: Hardware Error
-2: Busy
-3: Parameter Error (Subfunction invalid, invalid work
area address, invalid work area size)
-9002: Partition does not have authority to perform this
function
-5: Buffer was too small to supply requested data
0: Success
990x: Extended delay
Next Sequence Number
Return this integer as the
Sequence Number parameter on the next call,
or 1 if no more calls are required.
When 990x
Status is returned, it is suggested that software
delay for 10 raised to the x milliseconds (where x is the last digit of
the 990x return code), before calling the
ibm,lpar-perftools call with the same input
parameters. However, software may issue the
ibm,lpar-perftools call again earlier or later than
this.
R1--3.
For the Performance Tool Support option: For
subfunction value 1, on input the first 8 bytes of
the work area must contain the hypervisor IAR address to be converted. On
output, the first 8 bytes of the work area contain the offset of this
address from the start of the hypervisor function, method or module,
followed by a NULL-terminated text string containing the name of the
hypervisor function, method or module. If the address is not a valid
address in the hypervisor, on output the buffer must contain 0x0 (8
bytes) followed by a NULL-terminated text string indicating that the
address was not valid.
R1--4.
For the Performance Tool support option: The work
area must reside in contiguous memory.
R1--5.
For the Performance Tool Support option: If a
Status of anything other than 0 is returned, the
contents of the work area are not defined.
R1--6.
For the Performance Tool Support option: A partition
must have at most one call to this function in process at a given time.
This means that if one processor in the partition initiates this call,
receives a Busy or Extended Delay return, and then another processor
calls this function with a sequence number of 1, a subsequent call using
the
Next Sequence Number returned to the first processor
results in a Parameter Error return code.