Remove vestiges of the short (16-bit) multiplier option (#432)

These aren't needed, and should have been removed in d1e8e62fee
("Remove option for "short" 16x16 bit multiplier", 2022-07-19), but
were missed.

Signed-off-by: Paul Mackerras <paulus@ozlabs.org>
master
Paul Mackerras 11 hours ago committed by GitHub
parent 463ac2e32e
commit 6ef9395f10
No known key found for this signature in database
GPG Key ID: B5690EEEBB952194

@ -220,7 +220,6 @@ architecture behaviour of decode2 is
OP_SHL => "010",
OP_SHR => "010",
OP_EXTSWSLI => "010",
OP_MUL_L64 => "011", -- muldiv_result
OP_BCREG => "101", -- ramspr_result
OP_RFID => "101",
OP_ADDG6S => "111", -- misc_result

@ -176,7 +176,6 @@ architecture behaviour of execute1 is
signal a_in, b_in, c_in : std_ulogic_vector(63 downto 0);
signal cr_in : std_ulogic_vector(31 downto 0);
signal xerc_in : xer_common_t;
signal mshort_p : std_ulogic_vector(31 downto 0) := (others => '0');

signal valid_in : std_ulogic;
signal ctrl: ctrl_t := ctrl_t_init;
@ -192,7 +191,6 @@ architecture behaviour of execute1 is
signal adder_result: std_ulogic_vector(63 downto 0);
signal misc_result: std_ulogic_vector(63 downto 0);
signal muldiv_result: std_ulogic_vector(63 downto 0);
signal shortmul_result: std_ulogic_vector(63 downto 0);
signal spr_result: std_ulogic_vector(63 downto 0);
signal next_nia : std_ulogic_vector(63 downto 0);
signal s1_sel : std_ulogic_vector(2 downto 0);
@ -601,7 +599,6 @@ begin
adder_result when "000",
logical_result when "001",
rotator_result when "010",
shortmul_result when "011",
muldiv_result when "100",
ramspr_result when "101",
misc_result when others;
@ -772,7 +769,6 @@ begin
x_to_mult_32s.subtract <= '0';
x_to_mult_32s.addend <= (others => '0');

shortmul_result <= std_ulogic_vector(resize(signed(mshort_p), 64));
case ex1.mul_select is
when "00" =>
muldiv_result <= multiply_to_x.result(63 downto 0);
@ -1301,13 +1297,12 @@ begin
if e_in.is_32bit = '1' then
v.se.mult_32s := '1';
v.res2_sel := "00";
slow_op := '1';
else
-- Use standard multiplier
v.start_mul := '1';
slow_op := '1';
owait := '1';
end if;
slow_op := '1';

when OP_MUL_H64 =>
v.start_mul := '1';

Loading…
Cancel
Save