ECP5: Adjust PLL constants so the PLL lock indication works

At present, code (such as simple_random) which produces serial port
output during the first few milliseconds of operation produces garbled
output.  The reason is that the clock has not yet stabilized and is
running slow, resulting in the bit time of the serial characters being
too long.

The ECP5 data sheet says that the phase detector should be operated
between 10 and 400 MHz.  The current code operates it at 2MHz.
Consequently, the PLL lock indication doesn't work, i.e. it is always
zero.  The current code works around that by inverting it, i.e. taking
the "not locked" indication to mean "locked".

Instead, we now run it at 12MHz, chosen because the common external
clock inputs on ECP5 boards are 12MHz and 48MHz.  Normally this would
mean that the available system clock frequencies would be multiples of
12MHz, but this is a little inconvenient as we use 40MHz on the Orange
Crab v0.21 boards.  Instead, by using the secondary clock output for
feedback, we can have any divisor of the PLL frequency as the system
clock frequency.

The ECP5 data sheet says the PLL oscillator can run at 400 to 800
MHz.  Here we choose 480MHz since that allows us to generate 40MHz and
48MHz easily and is a multiple of 12MHz.

With this, the lock signal works correctly, and the inversion can be
removed.

Signed-off-by: Paul Mackerras <paulus@ozlabs.org>
pull/337/head
Paul Mackerras 3 years ago
parent 8a030502a2
commit d458b5845c

@ -82,33 +82,42 @@ architecture bypass of clock_generator is
CLKINTFB : out std_logic );
end component;

signal clkos : std_ulogic;
signal clkop : std_logic;
signal lock : std_logic;

-- PLL constants based on prjtrellis example
constant PLL_IN : natural := 2000000;
constant PLL_OUT : natural := 600000000;
-- PLL constants
-- According to the datasheet, PLL_IN needs to be between 10 and 400 MHz
-- PLL_OUT needs to be between 400 and 800 MHz
-- PLL_IN is chosen based on 12 and 48 MHz being common values
-- for the reference clock.
constant PLL_IN : natural := 12000000;
constant PLL_OUT : natural := 480000000;

-- Configration for ECP5 PLL
constant PLL_CLKOP_DIV : natural := PLL_OUT/CLK_OUTPUT_HZ;
constant PLL_CLKFB_DIV : natural := CLK_OUTPUT_HZ/PLL_IN;
constant PLL_CLKOS_DIV : natural := 2;
constant PLL_CLKFB_DIV : natural := PLL_OUT/PLL_CLKOS_DIV/PLL_IN;
constant PLL_CLKI_DIV : natural := CLK_INPUT_HZ/PLL_IN;

begin
pll_clk_out <= clkop;
pll_locked_out <= not lock; -- FIXME: EHXPLLL lock signal active low?!?
pll_locked_out <= lock;

clkgen: EHXPLLL
generic map(
CLKOP_CPHASE => 11, -- FIXME: Copied from prjtrells.
CLKOP_DIV => PLL_CLKOP_DIV,
CLKOS_ENABLE => "ENABLED",
CLKOS_DIV => PLL_CLKOS_DIV,
CLKFB_DIV => PLL_CLKFB_DIV,
CLKI_DIV => PLL_CLKI_DIV
CLKI_DIV => PLL_CLKI_DIV,
FEEDBK_PATH => "CLKOS"
)
port map (
CLKI => ext_clk,
CLKOP => clkop,
CLKFB => clkop,
CLKOS => clkos,
CLKFB => clkos,
LOCK => lock,
RST => pll_rst_in,
PHASESEL1 => '0',
@ -118,8 +127,8 @@ begin
PHASELOADREG => '0',
STDBY => '0',
PLLWAKESYNC => '0',
ENCLKOP => '0',
ENCLKOS => '0',
ENCLKOP => '1',
ENCLKOS => '1',
ENCLKOS2 => '0',
ENCLKOS3 => '0'
);

Loading…
Cancel
Save