FPU: Avoid adding bias twice in UE=1 underflow case

In case of underflow with UE=1, ROUND_UFLOW state adds the exponent
bias and then goes to NORMALIZE state if the value is not normalized.
Then NORMALIZE state will go back to ROUND_UFLOW if the exponent is
still tiny, resulting in the bias getting added twice.  To avoid this,
if ROUND_UFLOW needs to do normalization, it goes to a new NORM_UFLOW
state which does the normalization and goes to ROUNDING state.

Signed-off-by: Paul Mackerras <paulus@ozlabs.org>
pull/457/head
Paul Mackerras 2 weeks ago
parent a0755935f4
commit e5651e2eab

@ -72,7 +72,7 @@ architecture behaviour of fpu is
INT_SHIFT, INT_ROUND, INT_ISHIFT,
INT_FINAL, INT_CHECK, INT_OFLOW,
FINISH, NORMALIZE,
ROUND_UFLOW, ROUND_OFLOW,
ROUND_UFLOW, NORM_UFLOW, ROUND_OFLOW,
ROUNDING, ROUND_INC, ROUNDING_2, ROUNDING_3,
DENORM,
RENORM_A, RENORM_B, RENORM_C,
@ -2459,12 +2459,22 @@ begin
re_set_result <= '1';
if r.r(UNIT_BIT) = '0' then
rs_norm <= '1';
v.state := NORMALIZE;
v.state := NORM_UFLOW;
else
v.state := ROUNDING;
end if;
end if;

when NORM_UFLOW =>
-- normalize for UE=1 underflow case
-- r.shift = clz(r.r) - 7
opsel_r <= RES_SHIFT;
set_r := '1';
re_sel2 <= REXP2_NE;
re_set_result <= '1';
set_x := '1';
v.state := ROUNDING;

when ROUND_OFLOW =>
rcls_op <= RCLS_TINF;
v.fpscr(FPSCR_OX) := '1';
@ -2560,8 +2570,8 @@ begin
rcls_op <= RCLS_TZERO;
-- If the result is zero, that's handled below.
-- Renormalize result after rounding
re_set_result <= '1';
v.denorm := exp_tiny;
re_set_result <= '1';
if new_exp < to_signed(-1022, EXP_BITS) then
v.state := DENORM;
else