This implements the byte-reverse halfword, word and doubleword
instructions: brh, brw, and brd. These instructions were added to the
ISA in version 3.1. They use a new OP_BREV insn_type value. The
logic for these instructions is implemented in logical.vhdl.
In order to avoid going over 64 insn_type values, OP_AND and OP_OR
were combined into OP_LOGIC, which is like OP_AND except that the RS
input can be inverted as well as the RB input. The various forms of
OR instruction are then implemented using the identity
a OR b = NOT (NOT a AND NOT b)
The 'is_signed' field of the instruction decode table is used to
indicate that RS should be inverted.
Signed-off-by: Paul Mackerras <paulus@ozlabs.org>
This implements the setbc, setnbc, setbcr and setnbcr instructions.
Because the insn_type_t type already has 64 elements, this uses the
existing OP_SETB for the new instructions, and has execute1 compute
different results depending on bits 6-9 of the instruction.
Signed-off-by: Paul Mackerras <paulus@ozlabs.org>
This arranges to generate an illegal instruction type program
interrupt for illegal prefixed instructions, that is, those where the
suffix is not a legal value given the prefix, or the prefix has a
reserved value in the subtype field. This implementation doesn't
generate an interrupt for the invalid 8LS:D and MLS:D instruction
forms where R = 1 and RA != 0. (In those cases it uses (RA) as the
addend, i.e. it ignores the R bit.)
This detects the case where the address of an instruction prefix is
equal mod 64 to 60, and generates an alignment interrupt in that case.
This also arranges to set bit 34 of SRR1 when an interrupt occurs due
to a prefixed instruction, for those interrupts where that is required
(i.e. trace, alignment, floating-point unavailable, data storage, data
segment, and most cases of program interrupt).
Signed-off-by: Paul Mackerras <paulus@ozlabs.org>
This moves the insn_code values for mcrfs, mtfsb0/1 and mtfsfi into
the region used for floating-point instructions. This means that in
no-FPU implementations, they will get turned into illegal instructions
in predecode. We then don't need the code in execute1 that makes FP
instructions illegal in no-FPU implementations.
We also remove the NONE value for unit_t, since it was only ever used
with insn_type = OP_ILLEGAL, and the check for unit = NONE was
redundant with the check for insn_type = OP_ILLEGAL. Thus the check
for unit = NONE is no longer needed and is removed here.
Signed-off-by: Paul Mackerras <paulus@ozlabs.org>
This adds a "not HAS_FPU" condition in a few places to make it obvious
that logic to interface to the divide unit is not included when we
have an FPU.
Signed-off-by: Paul Mackerras <paulus@ozlabs.org>
Now that we have a 33 bit x 33 bit signed multiplier in execute1,
there is really no need for the 16 bit multiplier. The coremark
results are just as good without it as with it. This removes the
option for the sake of simplicity.
Signed-off-by: Paul Mackerras <paulus@ozlabs.org>
This adds an 'is_signed' signal to MultiplyInputType to indicate
whether the data1 and data2 fields are to be interpreted as signed or
unsigned numbers.
The 'not_result' field is replaced by a 'subtract' field which
provides a more intuitive interface for requesting that the product be
subtracted from the addend rather than added, i.e. subtract = 1 gives
C - A * B, vs. subtract = 0 giving C + A * B. (Previously the users
of the multipliers got the same effect by complementing the addend and
setting not_result = 1.)
The is_32bit field is removed because it is no longer used now that we
have a separate 32-bit multiplier.
Signed-off-by: Paul Mackerras <paulus@ozlabs.org>
This adds a pipelined 33-bit by 33-bit signed multiplier with one
cycle latency to the execute pipeline, and uses it for the mullw,
mulhw and mulhwu instructions. Because it has one cycle of latency we
can assume that its result is available in the second execute stage
without needing to add busy logic to the second stage.
This adds both a generic version of the multiplier and a
Xilinx-specific version using four DSP slices of the Artix-7.
Signed-off-by: Paul Mackerras <paulus@ozlabs.org>
This expands the field in the log buffer that stores the instruction
fetched from the icache to 36 bits, so that we get the insn_code and
illegal instruction indication. To do this, we reclaim 3 unused bits
from execute1's portion and one other unused bit (previously just set
to 0 in core.vhdl).
This also alters the trigger behaviour to stop after one quarter of
the log buffer has been filled with samples after the trigger, or 256
entries, whichever is less. This is to ensure that the trigger event
doesn't get overwritten when the log buffer is small.
This updates fmt_log to the new log format. Valid instructions are
printed as a decimal insn_code value followed by the bottom 26 bits of
the instruction. Illegal instructions are printed as "ill" followed
by the full 32 bits of the instruction.
Signed-off-by: Paul Mackerras <paulus@ozlabs.org>
This changes code that previously looked at the primary opcode (bits
26 to 31) of the instruction to use other methods, in places other
than in stage0 of decode1.
* Extend rc_t to have a new value, RCOE, indicating that the
instruction has both Rc and OE bits.
* Decode2 now tells execute1 whether the instruction has a third
operand, used for distinguishing between multiply and multiply-add
instructions.
* The invert_a field of the decode ROM is overloaded for load/store
instructions to indicate cache-inhibited loads and stores.
Signed-off-by: Paul Mackerras <paulus@ozlabs.org>
Do more decoding of the instruction ahead of the IDLE state
processing so that the IDLE state code becomes much simpler.
To make the decoding easier, we now use four insn_type_t codes for
floating-point operations rather than two. This also rearranges the
insn_type_t values a little to get the 4 FP opcode values to differ
only in the bottom 2 bits, and put OP_DIV, OP_DIVE and OP_MOD next to
them.
Signed-off-by: Paul Mackerras <paulus@ozlabs.org>
Instead of having a multiplexer in loadstore1 in order to be able to
put the instruction address into v.addr, we now set decode.input_reg_a
to CIA in the decode table entry for OP_FETCH_FAILED. That means that
the operand selection machinery in decode2 will supply the instruction
address to loadstore1 on the lv.addr1 input and no special case is
needed in loadstore1. This saves a few LUTs (~40 on the Artix-7).
Signed-off-by: Paul Mackerras <paulus@ozlabs.org>
This fixes a bug which causes a trace interrupt to store the wrong
value in SRR0 in the case where the instruction that has just
completed is followed by a sc (system call) instruction. What happens
is that first the traced instruction sets ex1.trace_next. Then, when
the sc instruction following it comes in, the execute1_actions process
sets v.e.last_nia to next_nia because it is an sc instruction, even
though it is not going to be executed -- we are going to take the
trace interrupt instead. Then when the trace interrupt is taken, we
incorrectly set SRR0 to the incremented address (the address of the
instruction following the sc).
To fix this, we have execute1_actions set a new flag if the current
instruction is sc, and only set v.e.last_nia to next_nia if we
actually execute the sc (in the "if go = '1'" case).
Fixes: 813e2317bf ("execute1: Restructure to separate out execution of side effects", 2022-06-18)
Reported-by: Anton Blanchard <anton@linux.ibm.com>
Signed-off-by: Paul Mackerras <paulus@ozlabs.org>
This provides access to the SPRs via the JTAG DMI interface. For now
they are still accessed as if they were GPR/FPRs using the same
numbering as before (GPRs at 0 - 0x1f, SPRs at 0x20 - 0x2d, FPRs at
0x40 - 0x5f).
For XER, debug reads now report the full value, not just the bits that
were previously stored in the register file. The "slow" SPR mux is
not used for debug reads.
Decode2 determines on each cycle whether a debug SPR access will
happen next cycle, based on whether there is a request and whether the
current instruction accesses the SPR RAM.
Signed-off-by: Paul Mackerras <paulus@ozlabs.org>
With this, the register file now contains 64 entries, for 32 GPRs and
32 FPRs, rather than the 128 it had previously. Several things get
simplified - decode1 no longer has to work out the ispr{1,2,o} values,
decode_input_reg_{a,b,c} no longer have the t = SPR case, etc.
Signed-off-by: Paul Mackerras <paulus@ozlabs.org>
By putting CTR on the odd side and LR and TAR on the even side, we can
read and write CTR for bdnz-style instructions in parallel with
reading LR or TAR for indirect branches and writing LR for branches
with LK=1. Thus we don't need to double up any of these instructions,
giving a simplification in decode2.
We now have logic for printing LR and CTR at the end of a simulation
in execute1, in addition to the similar logic in register_file and
cr_file.
Signed-off-by: Paul Mackerras <paulus@ozlabs.org>
This starts the process of removing SPRs from the register file by
moving SRR0/1, SPRG0-3, HSRR0/1 and HSPRG0/1 out of the register file
and putting them into execute1. They are stored in a pair of small
RAM arrays, referred to as "even" and "odd". The reason for having
two arrays is so that two values can be read and written in each
cycle. For example, SRR0 and SRR1 can be written in parallel by an
interrupt and read in parallel by the rfid instruction.
The addresses in the RAM which will be accessed are determined in the
decode2 stage. We have one write address for both sides, but two read
addresses, since in future we will want to be able to read CTR at the
same time as either LR or TAR.
We now have a connection from writeback to execute1 which carries the
partial SRR1 value for an interrupt. SRR0 comes from the execute
pipeline; we no longer need to carry instruction addresses along the
LSU and FPU pipelines. Since SRR0 and SRR1 can be written in the same
cycle now, we don't need the little state machine in writeback any
more.
Signed-off-by: Paul Mackerras <paulus@ozlabs.org>
- Arrange for XER to be written for OE=1 forms
- Arrange for condition codes to be set for RC=1 forms
(including correct handling for 32-bit mode)
- Don't instantiate the divider if we have an FPU.
Signed-off-by: Paul Mackerras <paulus@ozlabs.org>
This adds logic to the FPU to accomplish 64-bit integer divisions.
No instruction actually uses this yet.
The algorithm used is to obtain an estimate of the reciprocal of the
divisor using the lookup table and refine it by one to three
iterations of the Newton-Raphson algorithm (the number of iterations
depends on the number of significant bits in the dividend). Then the
reciprocal is multiplied by the dividend to get the quotient estimate.
The remainder is calculated as dividend - quotient * divisor. If the
remainder is greater than or equal to the divisor, the quotient is
incremented, or if a modulo operation is being done, the divisor is
subtracted from the remainder. The inverse estimate after refinement
is good enough that the quotient estimate is always equal to or one
less than the true quotient.
Signed-off-by: Paul Mackerras <paulus@ozlabs.org>
This provides a mechanism for tracking updates to the XER overflow
bits (SO, OV, OV32) and stalling instructions which need current
values of those bits (mfxer, integer compare instructions, integer
Rc=1 instructions, addex) or which writes carry bits (since all the
XER common bits are written together, if we are writing CA/CA32 we
need up-to-date values of SO/OV/OV32).
This will enable updates to SO/OV/OV32 to be done at other places
besides the ex1 stage.
Signed-off-by: Paul Mackerras <paulus@ozlabs.org>
This makes the FPU able to stall other units at execute stage 2 and be
stalled by other units (specifically the LSU).
This means that the completion and writeback for an instruction can
now end up being deferred until the second cycle of a following
instruction, i.e. the cycle when the state machine has gone through
IDLE state into one of the DO_* states, which means we need to latch
the destination FPR number, CR mask, etc. from the previous
instruction so that we present the correct information to writeback.
The advantage of this is that we can get rid of the in_progress signal
from the LSU.
Signed-off-by: Paul Mackerras <paulus@ozlabs.org>
This lets us forward the CR0 result to following instructions that
use CR, meaning they get to issue one cycle earlier.
Signed-off-by: Paul Mackerras <paulus@ozlabs.org>
Execute1 and loadstore1 now send each other stall signals that
indicate that a valid instruction in stage 2 can't complete in this
cycle, and hence any valid instruction in stage 1 in the other unit
can't move to stage 2. With this in place, an ALU instruction can
move into stage 1 while a LSU instruction is in stage 2.
Since the FPU doesn't yet have a way to stall completion, we can't yet
start FPU instructions while any LSU or ALU instruction is in
progress.
Signed-off-by: Paul Mackerras <paulus@ozlabs.org>
This enables some instructions to issue earlier and thus improves
performance, at the cost of some extra multiplexers in decode2.
Signed-off-by: Paul Mackerras <paulus@ozlabs.org>
This adds a second execute stage to the pipeline, in order to match up
the length of the pipeline through loadstore and dcache with the
length through execute1. This will ultimately enable us to get rid of
the 1-cycle bubble that we currently have when issuing ALU
instructions after one or more LSU instructions.
Most ALU instructions execute in the first stage, except for
count-zeroes and popcount instructions (which take two cycles and do
some of their work in the second stage) and mfspr/mtspr to "slow" SPRs
(TB, DEC, PVR, LOGA/LOGD, CFAR). Multiply and divide/mod instructions
take several cycles but the instruction stays in the first stage (ex1)
and ex1.busy is asserted until the operation is complete.
There is currently a bypass from the first stage but not the second
stage. Performance is down somewhat because of that and because this
doesn't yet eliminate the bubble between LSU and ALU instructions.
The forwarding of XER common bits has been changed somewhat because
now there is another pipeline stage between ex1 and the committed
state in cr_file. The simplest thing for now is to record the last
value written and use that, unless there has been a flush, in which
case the committed state (obtained via e_in.xerc) is used.
Note that this fixes what was previously a benign bug in control.vhdl,
where it was possible for control to forget an instructions dependency
on a value from a previous instruction (a GPR or the CR) if this
instruction writes the value and the instruction gets to the point
where it could issue but is blocked by the busy signal from execute1.
In that situation, control may incorrectly not indicate that a bypass
should be used. That didn't matter previously because, for ALU and
FPU instructions, there was only one previous instruction in flight
and once the current instruction could issue, the previous instruction
was completing and the correct value would be obtained from
register_file or cr_file. For loadstore instructions there could be
two being executed, but because there are no bypass paths, failing to
indicate use of a bypass path is fine.
Signed-off-by: Paul Mackerras <paulus@ozlabs.org>
We now have a record that represents the actions taken in executing an
instruction, and a process that computes that for the incoming
instruction. We no longer have 'current' or 'r.cur_instr', instead
things like the destination register are put into r.e in the first
cycle of an instruction and not reinitialized in subsequent busy
cycles.
For mfspr and mtspr, we now decode "slow" SPR numbers (those SPRs that
are not stored in the register file) to a new "spr_selector" record
in decode1 (excluding those in the loadstore unit). With this, the
result for mfspr is determined in the data path.
Signed-off-by: Paul Mackerras <paulus@ozlabs.org>
Besides the overflow and status carry bits, XER has 18 bits which need
to retain the value written by mtxer (in case software wants to
emulate the move-assist instructions (lswi, lswx, stswi, stswx).
Until now these bits (and others) have been stored in the GPR file as
a "fast" SPR, but this causes complications because XER is not really
a fast SPR.
Instead, we now store these 18 bits in the 'ctrl' signal, which exists
in execute1. This will enable us to simplify the data path in future,
and has the added bonus that with a little bit of plumbing, we can get
the full XER value printed when dumping registers at the end of a
simulation.
Therefore this changes scripts/run_test.sh to remove the greps which
exclude XER from the comparison of actual and expected register
results.
Signed-off-by: Paul Mackerras <paulus@ozlabs.org>
This moves the calculation of the result for popcnt* into the
countbits unit, renamed from countzero, so that we can take two cycles
to get the result. The motivation for this is that the popcnt*
calculation was showing up as a critical path.
Signed-off-by: Paul Mackerras <paulus@ozlabs.org>
This adds an optional 16 bit x 16 bit signed multiplier and uses it
for multiply instructions that return the low 64 bits of the product
(mull[dw][o] and mulli, but not maddld) when the operands are both in
the range -2^15 .. 2^15 - 1. The "short" 16-bit multiplier produces
its result combinatorially, so a multiply that uses it executes in one
cycle. This improves the coremark result by about 4%, since coremark
does quite a lot of multiplies and they almost all have operands that
fit into 16 bits.
The presence of the short multiplier is controlled by a generic at the
execute1, SOC, core and top levels. For now, it defaults to off for
all platforms, and can be enabled using the --has_short_mult flag to
fusesoc.
Signed-off-by: Paul Mackerras <paulus@ozlabs.org>
- mcrxrx put the bits in the wrong order
- addpcis was setting CR0 if the instruction bit 0 = 1, which it
shouldn't
- bpermd was producing 0 always and additionally had the wrong bit
numbering
Signed-off-by: Paul Mackerras <paulus@ozlabs.org>
This implements most of the architected PMU events. The ones missing
are mostly the ones that depend on which level of the cache hierarchy
data is fetched from. The events implemented here, and their raw
event codes, are:
Floating-point operation completed (100f4)
Load completed (100fc)
Store completed (200f0)
Icache miss (200fc)
ITLB miss (100f6)
ITLB miss resolved (400fc)
Dcache load miss (400f0)
Dcache load miss resolved (300f8)
Dcache store miss (300f0)
DTLB miss (300fc)
DTLB miss resolved (200f6)
No instruction available and none being executed (100f8)
Instruction dispatched (200f2, 300f2, 400f2)
Taken branch instruction completed (200fa)
Branch mispredicted (400f6)
External interrupt taken (200f8)
Signed-off-by: Paul Mackerras <paulus@ozlabs.org>
This is the start of an implementation of a PMU according to PowerISA
v3.0B. Things not implemented yet include most architected events,
the BHRB, event-based branches, thresholding, MMCR0[TBCC] field, etc.
Signed-off-by: Paul Mackerras <paulus@ozlabs.org>
At present the logic prevents any interrupts from being handled while
there is a load/store instruction (one that has unit=LDST) being
executed. However, load/store instructions can still get sent to
loadstore1. Thus an instruction which should generate an interrupt
such as a floating-point unavailable interrupt will instead get
executed.
To fix this, when we detect that an interrupt should be generated but
loadstore1 is still executing a previous instruction, we don't execute
any new instructions, and set a new r.intr_pending flag. That results
in busy_out being asserted (meaning that no further instructions will
come in from decode2). When loadstore1 has finished the instructions
it has, the interrupt gets sent to writeback. If one of the
instructions in loadstore1 generates an interrupt in the meantime, the
l_in.interrupt signal gets asserted and that clears r.intr_pending, so
the interrupt we detected gets discarded.
Signed-off-by: Paul Mackerras <paulus@ozlabs.org>
The idea here is that we can have multiple instructions in progress at
the same time as long as they all go to the same unit, because that
unit will keep them in order. If we get an instruction for a
different unit, we wait for all the previous instructions to finish
before executing it. Since the loadstore unit is the only one that is
currently pipelined, this boils down to saying that loadstore
instructions can go ahead while l_in.in_progress = 1 but other
instructions have to wait until it is 0.
This gives a 2% increase on coremark performance on the Arty A7-100
(from ~190 to ~194).
Signed-off-by: Paul Mackerras <paulus@ozlabs.org>
This moves the logic for redirecting fetching and writing SRR0 and
SRR1 to writeback. The aim is that ultimately units other than
execute1 can send their interrupts to writeback along with their
instruction completions, so that there can be multiple instructions
in flight without needing execute1 to keep track of the address
of each outstanding instruction.
Signed-off-by: Paul Mackerras <paulus@ozlabs.org>
This changes the bypass path. Previously it went from after
execute1's output to after decode2's output. Now it goes from before
execute1's output register to before decode2's output register. The
reason is that the new path will be simpler to manage when there are
possibly multiple instructions in flight. This means that the
bypassing can be managed inside decode2 and control.
Signed-off-by: Paul Mackerras <paulus@ozlabs.org>
This changes the way GPR hazards are detected and tracked. Instead of
having a model of the pipeline in gpr_hazard.vhdl, which has to mirror
the behaviour of the real pipeline exactly, we now assign a 2-bit tag
to each instruction and record which GSPR the instruction writes.
Subsequent instructions that need to use the GSPR get the tag number
and stall until the value with that tag is being written back to the
register file.
For now, the forwarding paths are disabled. That gives about a 8%
reduction in coremark performance.
Signed-off-by: Paul Mackerras <paulus@ozlabs.org>
This uses the instruction doubling machinery to convert conditional
branch instructions that update both CTR and LR (e.g., bdnzl, bdnzlrl)
into two instructions, of which the first updates CTR and determines
whether the branch is taken, and the second updates LR and does the
redirect if necessary.
Signed-off-by: Paul Mackerras <paulus@ozlabs.org>
This uses the instruction-doubling machinery to send load with update
instructions down to loadstore1 as two separate ops, rather than
one op with two destinations. This will help to simplify the value
tracking mechanisms.
Signed-off-by: Paul Mackerras <paulus@ozlabs.org>