library ieee;
use ieee.std_logic_1164.all;
library work;
use work.common.all;
entity control is
generic (
PIPELINE_DEPTH : natural := 2
);
port (
clk : in std_ulogic;
rst : in std_ulogic;
complete_in : in instr_tag_t;
valid_in : in std_ulogic;
core: Implement quadword loads and stores This implements the lq, stq, lqarx and stqcx. instructions. These instructions all access two consecutive GPRs; for example the "lq %r6,0(%r3)" instruction will load the doubleword at the address in R3 into R7 and the doubleword at address R3 + 8 into R6. To cope with having two GPR sources or destinations, the instruction gets repeated at the decode2 stage, that is, for each lq/stq/lqarx/stqcx. coming in from decode1, two instructions get sent out to execute1. For these instructions, the RS or RT register gets modified on one of the iterations by setting the LSB of the register number. In LE mode, the first iteration uses RS|1 or RT|1 and the second iteration uses RS or RT. In BE mode, this is done the other way around. In order for decode2 to know what endianness is currently in use, we pass the big_endian flag down from icache through decode1 to decode2. This is always in sync with what execute1 is using because only rfid or an interrupt can change MSR[LE], and those operations all cause a flush and redirect. There is now an extra column in the decode tables in decode1 to indicate whether the instruction needs to be repeated. Decode1 also enforces the rule that lq with RT = RT and lqarx with RA = RT or RB = RT are illegal. Decode2 now passes a 'repeat' flag and a 'second' flag to execute1, and execute1 passes them on to loadstore1. The 'repeat' flag is set for both iterations of a repeated instruction, and 'second' is set on the second iteration. Execute1 does not take asynchronous or trace interrupts on the second iteration of a repeated instruction. Loadstore1 uses 'next_addr' for the second iteration of a repeated load/store so that we access the second doubleword of the memory operand. Thus loadstore1 accesses the doublewords in increasing memory order. For 16-byte loads this means that the first iteration writes GPR RT|1. It is possible that RA = RT|1 (this is a legal but non-preferred form), meaning that if the memory operand was misaligned, the first iteration would overwrite RA but then the second iteration might take a page fault, leading to corrupted state. To avoid that possibility, 16-byte loads in LE mode take an alignment interrupt if the operand is not 16-byte aligned. (This is the case anyway for lqarx, and we enforce it for lq as well.) Signed-off-by: Paul Mackerras <paulus@ozlabs.org>
4 years ago
repeated : in std_ulogic;
flush_in : in std_ulogic;
busy_in : in std_ulogic;
deferred : in std_ulogic;
sgl_pipe_in : in std_ulogic;
stop_mark_in : in std_ulogic;
gpr_write_valid_in : in std_ulogic;
gpr_write_in : in gspr_index_t;
gpr_bypassable : in std_ulogic;
gpr_a_read_valid_in : in std_ulogic;
gpr_a_read_in : in gspr_index_t;
gpr_b_read_valid_in : in std_ulogic;
gpr_b_read_in : in gspr_index_t;
gpr_c_read_valid_in : in std_ulogic;
gpr_c_read_in : in gspr_index_t;
cr_read_in : in std_ulogic;
cr_write_in : in std_ulogic;
cr_bypassable : in std_ulogic;
valid_out : out std_ulogic;
stall_out : out std_ulogic;
stopped_out : out std_ulogic;
gpr_bypass_a : out std_ulogic;
gpr_bypass_b : out std_ulogic;
gpr_bypass_c : out std_ulogic;
cr_bypass : out std_ulogic;
instr_tag_out : out instr_tag_t
);
end entity control;
architecture rtl of control is
type state_type is (IDLE, WAIT_FOR_PREV_TO_COMPLETE, WAIT_FOR_CURR_TO_COMPLETE);
type reg_internal_type is record
state : state_type;
outstanding : integer range -1 to PIPELINE_DEPTH+2;
end record;
constant reg_internal_init : reg_internal_type := (state => IDLE, outstanding => 0);
signal r_int, rin_int : reg_internal_type := reg_internal_init;
signal stall_a_out : std_ulogic;
signal stall_b_out : std_ulogic;
signal stall_c_out : std_ulogic;
signal cr_stall_out : std_ulogic;
signal gpr_write_valid : std_ulogic := '0';
signal cr_write_valid : std_ulogic := '0';
type tag_register is record
wr_gpr : std_ulogic;
reg : gspr_index_t;
recent : std_ulogic;
end record;
type tag_regs_array is array(tag_number_t) of tag_register;
signal tag_regs : tag_regs_array;
signal instr_tag : instr_tag_t;
signal gpr_tag_a : instr_tag_t;
signal gpr_tag_b : instr_tag_t;
signal gpr_tag_c : instr_tag_t;
signal gpr_tag_stall : std_ulogic;
signal curr_tag : tag_number_t;
signal next_tag : tag_number_t;
function tag_match(tag1 : instr_tag_t; tag2 : instr_tag_t) return boolean is
begin
return tag1.valid = '1' and tag2.valid = '1' and tag1.tag = tag2.tag;
end;
begin
cr_hazard0: entity work.cr_hazard
generic map (
PIPELINE_DEPTH => PIPELINE_DEPTH
)
port map (
clk => clk,
busy_in => busy_in,
deferred => deferred,
complete_in => complete_in.valid,
flush_in => flush_in,
issuing => valid_out,
cr_read_in => cr_read_in,
cr_write_in => cr_write_valid,
bypassable => cr_bypassable,
stall_out => cr_stall_out,
use_bypass => cr_bypass
);
gpr_bypass_a <= '0';
gpr_bypass_b <= '0';
gpr_bypass_c <= '0';
control0: process(clk)
begin
if rising_edge(clk) then
assert rin_int.outstanding >= 0 and rin_int.outstanding <= (PIPELINE_DEPTH+1)
report "Outstanding bad " & integer'image(rin_int.outstanding) severity failure;
r_int <= rin_int;
for i in tag_number_t loop
if rst = '1' or flush_in = '1' then
tag_regs(i).wr_gpr <= '0';
else
if complete_in.valid = '1' and i = complete_in.tag then
tag_regs(i).wr_gpr <= '0';
report "tag " & integer'image(i) & " not valid";
end if;
if gpr_write_valid = '1' and tag_regs(i).reg = gpr_write_in then
tag_regs(i).recent <= '0';
if tag_regs(i).recent = '1' and tag_regs(i).wr_gpr = '1' then
report "tag " & integer'image(i) & " not recent";
end if;
end if;
if instr_tag.valid = '1' and i = instr_tag.tag then
tag_regs(i).wr_gpr <= gpr_write_valid;
tag_regs(i).reg <= gpr_write_in;
tag_regs(i).recent <= gpr_write_valid;
if gpr_write_valid = '1' then
report "tag " & integer'image(i) & " valid for gpr " & to_hstring(gpr_write_in);
end if;
end if;
end if;
end loop;
if rst = '1' then
curr_tag <= 0;
else
curr_tag <= next_tag;
end if;
end if;
end process;
control_hazards : process(all)
variable gpr_stall : std_ulogic;
variable tag_a : instr_tag_t;
variable tag_b : instr_tag_t;
variable tag_c : instr_tag_t;
variable tag_s : instr_tag_t;
variable tag_t : instr_tag_t;
variable incr_tag : tag_number_t;
begin
tag_a := instr_tag_init;
for i in tag_number_t loop
if tag_regs(i).wr_gpr = '1' and tag_regs(i).recent = '1' and tag_regs(i).reg = gpr_a_read_in then
tag_a.valid := gpr_a_read_valid_in;
tag_a.tag := i;
end if;
end loop;
if tag_match(tag_a, complete_in) then
tag_a.valid := '0';
end if;
tag_b := instr_tag_init;
for i in tag_number_t loop
if tag_regs(i).wr_gpr = '1' and tag_regs(i).recent = '1' and tag_regs(i).reg = gpr_b_read_in then
tag_b.valid := gpr_b_read_valid_in;
tag_b.tag := i;
end if;
end loop;
if tag_match(tag_b, complete_in) then
tag_b.valid := '0';
end if;
tag_c := instr_tag_init;
for i in tag_number_t loop
if tag_regs(i).wr_gpr = '1' and tag_regs(i).recent = '1' and tag_regs(i).reg = gpr_c_read_in then
tag_c.valid := gpr_c_read_valid_in;
tag_c.tag := i;
end if;
end loop;
if tag_match(tag_c, complete_in) then
tag_c.valid := '0';
end if;
gpr_tag_a <= tag_a;
gpr_tag_b <= tag_b;
gpr_tag_c <= tag_c;
gpr_tag_stall <= tag_a.valid or tag_b.valid or tag_c.valid;
incr_tag := curr_tag;
instr_tag.tag <= curr_tag;
instr_tag.valid <= valid_out and not deferred;
if instr_tag.valid = '1' then
incr_tag := (curr_tag + 1) mod TAG_COUNT;
end if;
next_tag <= incr_tag;
instr_tag_out <= instr_tag;
end process;
control1 : process(all)
variable v_int : reg_internal_type;
variable valid_tmp : std_ulogic;
variable stall_tmp : std_ulogic;
begin
v_int := r_int;
-- asynchronous
valid_tmp := valid_in and not flush_in;
stall_tmp := '0';
if flush_in = '1' then
-- expect to see complete_in next cycle
v_int.outstanding := 1;
elsif complete_in.valid = '1' then
v_int.outstanding := r_int.outstanding - 1;
end if;
if rst = '1' then
v_int := reg_internal_init;
valid_tmp := '0';
end if;
-- Handle debugger stop
stopped_out <= '0';
if stop_mark_in = '1' and v_int.outstanding = 0 then
stopped_out <= '1';
end if;
-- state machine to handle instructions that must be single
-- through the pipeline.
case r_int.state is
when IDLE =>
if valid_tmp = '1' then
if (sgl_pipe_in = '1') then
if v_int.outstanding /= 0 then
v_int.state := WAIT_FOR_PREV_TO_COMPLETE;
stall_tmp := '1';
else
-- send insn out and wait on it to complete
v_int.state := WAIT_FOR_CURR_TO_COMPLETE;
end if;
else
-- let it go out if there are no GPR or CR hazards
stall_tmp := gpr_tag_stall or cr_stall_out;
end if;
end if;
when WAIT_FOR_PREV_TO_COMPLETE =>
if v_int.outstanding = 0 then
-- send insn out and wait on it to complete
v_int.state := WAIT_FOR_CURR_TO_COMPLETE;
else
stall_tmp := '1';
end if;
when WAIT_FOR_CURR_TO_COMPLETE =>
if v_int.outstanding = 0 then
v_int.state := IDLE;
-- XXX Don't replicate this
if valid_tmp = '1' then
if (sgl_pipe_in = '1') then
if v_int.outstanding /= 0 then
v_int.state := WAIT_FOR_PREV_TO_COMPLETE;
stall_tmp := '1';
else
-- send insn out and wait on it to complete
v_int.state := WAIT_FOR_CURR_TO_COMPLETE;
end if;
else
-- let it go out if there are no GPR or CR hazards
stall_tmp := gpr_tag_stall or cr_stall_out;
end if;
end if;
else
stall_tmp := '1';
end if;
end case;
if stall_tmp = '1' then
valid_tmp := '0';
end if;
gpr_write_valid <= gpr_write_valid_in and valid_tmp;
cr_write_valid <= cr_write_in and valid_tmp;
if valid_tmp = '1' and deferred = '0' then
v_int.outstanding := v_int.outstanding + 1;
end if;
-- update outputs
valid_out <= valid_tmp;
stall_out <= stall_tmp or deferred;
-- update registers
rin_int <= v_int;
end process;
end;