library ieee;
|
|
use ieee.std_logic_1164.all;
|
|
use ieee.numeric_std.all;
|
|
|
|
entity cr_hazard is
|
|
generic (
|
|
PIPELINE_DEPTH : natural := 2
|
|
);
|
|
port(
|
|
clk : in std_logic;
|
|
|
|
cr_read_in : in std_ulogic;
|
|
cr_write_in : in std_ulogic;
|
|
|
|
stall_out : out std_ulogic
|
|
);
|
|
end entity cr_hazard;
|
|
architecture behaviour of cr_hazard is
|
|
type pipeline_entry_type is record
|
|
valid : std_ulogic;
|
|
end record;
|
|
constant pipeline_entry_init : pipeline_entry_type := (valid => '0');
|
|
|
|
type pipeline_t is array(0 to PIPELINE_DEPTH-1) of pipeline_entry_type;
|
|
constant pipeline_t_init : pipeline_t := (others => pipeline_entry_init);
|
|
|
|
signal r, rin : pipeline_t := pipeline_t_init;
|
|
begin
|
|
cr_hazard0: process(clk)
|
|
begin
|
|
if rising_edge(clk) then
|
|
r <= rin;
|
|
end if;
|
|
end process;
|
|
|
|
cr_hazard1: process(all)
|
|
variable v : pipeline_t;
|
|
begin
|
|
v := r;
|
|
|
|
stall_out <= '0';
|
|
loop_0: for i in 0 to PIPELINE_DEPTH-1 loop
|
|
if (r(i).valid = cr_read_in) then
|
|
stall_out <= '1';
|
|
end if;
|
|
end loop;
|
|
|
|
v(0).valid := cr_write_in;
|
|
loop_1: for i in 0 to PIPELINE_DEPTH-2 loop
|
|
-- propagate to next slot
|
|
v(i+1) := r(i);
|
|
end loop;
|
|
|
|
-- asynchronous output
|
|
if cr_read_in = '0' then
|
|
stall_out <= '0';
|
|
end if;
|
|
|
|
-- update registers
|
|
rin <= v;
|
|
|
|
end process;
|
|
end;
|