title: Advanced Accelerator Adapter 25Gbps I/O Compliance Specification
|
|
group: accelerator
|
|
publicreview: false
|
|
tags:
|
|
- specification
|
|
- compliance
|
|
- testharness
|
|
- testsuite
|
|
- 25gbps
|
|
- 25gio
|
|
- advancedacceleratoradapter
|
|
- accelerator
|
|
- capi30
|
|
- opencapi
|
|
date: 2018-11-05
|
|
draft: false
|
|
---
|
|
|
|
The purpose of the OpenPOWER Advanced Accelerator Adapter Compliance 25Gbps I/O Test Harness and Test Suite specification is
|
|
to provide the test suite requirements to demonstrate OpenPOWER Advanced Accelerator Adapter 25G I/O compliance for POWER9™ systems.
|
|
|
|
The input to this specification is the following specification :
|
|
OpenPOWER Advanced Accelerator Adapter Electro-Mechanical Specification
|
|
which describes electro-mechanical specification for advanced accelerator adapters within the OpenPOWER ecosystem supported by IBM POWER9.
|
|
|
|
There are two accelerator approaches for the 25Gbit/sec interface and
|
|
the compliance for each approach is defined in this document.
|
|
The first approach is a Mezzanine Adapter Card which is attached to the system planar via two connectors.
|
|
The Mezzanine Adapter Card for OpenPOWER systems based on the POWER9 processor attaches to the 25Gbit/sec interface native to
|
|
the POWER9 and plugs into the mezzanine card connectors.
|
|
|
|
The second approach is a Cabled Interface Extension to an adapter card.
|
|
It uses a PCIe card as an example but the cabled extension does not require the adapter card be PCIe.
|
|
POWER9 platforms support the optional cabling of the 25Gbit/sec Advanced Accelerator Interface to
|
|
the advanced accelerator adapter in a riser card plugged into a PCIe slot in the same system.
|
|
In addition, the adapter could be located in different drawer of the rack.
|
|
|
|
This document is a Standard Track, Work Group Specification work product owned by the Compliance Workgroup and
|
|
handled in compliance with the requirements outlined in the OpenPOWER Foundation Work Group (WG) Process document.
|
|
Comments, questions, etc. can be submitted to the public mailing list for this document at <openpower-25gio-thts@mailinglist.openpowerfoundation.org>.
|