This reduces the set of instructions marked as single-issue to just
attn and mtspr to "slow" SPRs (those that are not stored in the
register file).
The instructions that were previously single-issue are: isync, dcbf,
dcbst, dcbt, dcbtst, eieio, icbi, mfmsr, mtmsr, mtmsrd, mfspr to slow
SPRS, sync, tlbsync and wait. The synchronization instructions are
mostly no-ops anyway due to the in-order nature of the core, and the
cache-management instructions are unimplemented (except for icbi).
The MSR ops don't need to be single-issue due to the in-order core and
the fact that MSR updates are effective on the following instruction.
Signed-off-by: Paul Mackerras <paulus@ozlabs.org>
This makes the FPU able to stall other units at execute stage 2 and be
stalled by other units (specifically the LSU).
This means that the completion and writeback for an instruction can
now end up being deferred until the second cycle of a following
instruction, i.e. the cycle when the state machine has gone through
IDLE state into one of the DO_* states, which means we need to latch
the destination FPR number, CR mask, etc. from the previous
instruction so that we present the correct information to writeback.
The advantage of this is that we can get rid of the in_progress signal
from the LSU.
Signed-off-by: Paul Mackerras <paulus@ozlabs.org>
This lets us forward the CR0 result to following instructions that
use CR, meaning they get to issue one cycle earlier.
Signed-off-by: Paul Mackerras <paulus@ozlabs.org>
Execute1 and loadstore1 now send each other stall signals that
indicate that a valid instruction in stage 2 can't complete in this
cycle, and hence any valid instruction in stage 1 in the other unit
can't move to stage 2. With this in place, an ALU instruction can
move into stage 1 while a LSU instruction is in stage 2.
Since the FPU doesn't yet have a way to stall completion, we can't yet
start FPU instructions while any LSU or ALU instruction is in
progress.
Signed-off-by: Paul Mackerras <paulus@ozlabs.org>
This enables some instructions to issue earlier and thus improves
performance, at the cost of some extra multiplexers in decode2.
Signed-off-by: Paul Mackerras <paulus@ozlabs.org>
This adds a second execute stage to the pipeline, in order to match up
the length of the pipeline through loadstore and dcache with the
length through execute1. This will ultimately enable us to get rid of
the 1-cycle bubble that we currently have when issuing ALU
instructions after one or more LSU instructions.
Most ALU instructions execute in the first stage, except for
count-zeroes and popcount instructions (which take two cycles and do
some of their work in the second stage) and mfspr/mtspr to "slow" SPRs
(TB, DEC, PVR, LOGA/LOGD, CFAR). Multiply and divide/mod instructions
take several cycles but the instruction stays in the first stage (ex1)
and ex1.busy is asserted until the operation is complete.
There is currently a bypass from the first stage but not the second
stage. Performance is down somewhat because of that and because this
doesn't yet eliminate the bubble between LSU and ALU instructions.
The forwarding of XER common bits has been changed somewhat because
now there is another pipeline stage between ex1 and the committed
state in cr_file. The simplest thing for now is to record the last
value written and use that, unless there has been a flush, in which
case the committed state (obtained via e_in.xerc) is used.
Note that this fixes what was previously a benign bug in control.vhdl,
where it was possible for control to forget an instructions dependency
on a value from a previous instruction (a GPR or the CR) if this
instruction writes the value and the instruction gets to the point
where it could issue but is blocked by the busy signal from execute1.
In that situation, control may incorrectly not indicate that a bypass
should be used. That didn't matter previously because, for ALU and
FPU instructions, there was only one previous instruction in flight
and once the current instruction could issue, the previous instruction
was completing and the correct value would be obtained from
register_file or cr_file. For loadstore instructions there could be
two being executed, but because there are no bypass paths, failing to
indicate use of a bypass path is fine.
Signed-off-by: Paul Mackerras <paulus@ozlabs.org>
We now have a record that represents the actions taken in executing an
instruction, and a process that computes that for the incoming
instruction. We no longer have 'current' or 'r.cur_instr', instead
things like the destination register are put into r.e in the first
cycle of an instruction and not reinitialized in subsequent busy
cycles.
For mfspr and mtspr, we now decode "slow" SPR numbers (those SPRs that
are not stored in the register file) to a new "spr_selector" record
in decode1 (excluding those in the loadstore unit). With this, the
result for mfspr is determined in the data path.
Signed-off-by: Paul Mackerras <paulus@ozlabs.org>
Besides the overflow and status carry bits, XER has 18 bits which need
to retain the value written by mtxer (in case software wants to
emulate the move-assist instructions (lswi, lswx, stswi, stswx).
Until now these bits (and others) have been stored in the GPR file as
a "fast" SPR, but this causes complications because XER is not really
a fast SPR.
Instead, we now store these 18 bits in the 'ctrl' signal, which exists
in execute1. This will enable us to simplify the data path in future,
and has the added bonus that with a little bit of plumbing, we can get
the full XER value printed when dumping registers at the end of a
simulation.
Therefore this changes scripts/run_test.sh to remove the greps which
exclude XER from the comparison of actual and expected register
results.
Signed-off-by: Paul Mackerras <paulus@ozlabs.org>
Simplify the flow control by stalling the whole upstream pipeline when
a stage can't proceed, instead of trying to let each stage progress
independently when it can.
Signed-off-by: Paul Mackerras <paulus@ozlabs.org>
While these signals should only be read when valid is true, they
are only a small number of bits and we want to reduce the amount of
U/X state bouncing around the chip.
Signed-off-by: Anton Blanchard <anton@linux.ibm.com>
decode1 has a lot of logic that uses i_out.insn without first looking at
i_iout.valid. Play it safe and never output X state.
Signed-off-by: Anton Blanchard <anton@linux.ibm.com>
While we should only look at this when d_out.valid = 1, we may as remove
some U state across interfaces.
Signed-off-by: Anton Blanchard <anton@linux.ibm.com>
While this is not an issue in VHDL, I noticed this when running
a script over the source and we may as well fix it.
Signed-off-by: Anton Blanchard <anton@linux.ibm.com>
While trying to reduce U/X state issues, I notice that our BSS is not
being initialised in the hello world test.
Signed-off-by: Anton Blanchard <anton@linux.ibm.com>
These instructions are similar to those at
https://ozlabs.org/~joel/microwatt/README
except they describe how to build the artifacts from scratch instead of
downloading them.
Signed-off-by: Joel Stanley <joel@jms.id.au>
The SoC defaults to using the uart16550 so provide instructions on how
to fetch that library when seetting up fusesoc.
Also remove the text about a working directory; fusesoc doesn't need
one.
Signed-off-by: Joel Stanley <joel@jms.id.au>
log2ceil() returns the number of bits required to store a value, so we
need to pass in memory_size-1, not memory_size.
Every other user of log2ceil() gets this right.
Signed-off-by: Anton Blanchard <anton@linux.ibm.com>